Special Transformers

Dry-type and oil-immersed transformers for furnace, rectifier, traction, test-bay and isolation duty, where a distribution transformer would not survive the load profile.

Rated power
25 – 25 000 kVA
Primary voltage
up to 35 kV
Vector group
Dyn11, Yyn0, Dd0, special
Insulation
Class B / F / H
Cooling
AN / AF / ONAN / ONAF
Duty
Furnace, rectifier, traction, test
Overview

A furnace transformer sees a short-circuit every time the electrodes strike. A rectifier transformer feeds a load that is not sinusoidal. A test transformer has to be stable at 5 % of its rating. None of these are distribution duty.

Electromash designs to the duty cycle supplied by the customer, including harmonic spectrum, K-factor and the expected number of through-faults over the life of the unit.

Both dry cast-resin and oil-immersed constructions are available, with off-circuit and on-load tap changers.

Key characteristics

Designed to the actual load spectrum

Harmonic content and duty cycle are design inputs, not a derating factor applied afterwards.

Through-fault withstand verified

Winding bracing dimensioned for the declared number and magnitude of short-circuit events.

Multi-secondary configurations

Phase-shifted secondaries for 12- and 24-pulse rectifier arrangements.

Replacement to existing footprint

Tank, bushing positions and rail centres can be matched to the transformer being replaced.

Construction

  • Cast-resin or oil-immersed core-form construction
  • Copper foil or disc windings depending on current and impulse level
  • Electrostatic shield between windings on isolation duty
  • Buchholz, oil level, winding and oil temperature protection
  • Off-circuit tap changer ±2 × 2.5 % as standard

Available configurations

  • Furnace, rectifier, traction, isolation, earthing, test duty
  • Dry cast-resin (AN / AF) or oil-immersed (ONAN / ONAF)
  • Off-circuit or on-load tap changer
  • 12- or 24-pulse multi-secondary
  • Seismic and marine qualification on request

Monitoring options

  • Winding temperature via Pt100 and thermal image relay
  • Oil temperature and level
  • Buchholz gas and surge protection
  • Fan and pump control contacts
Model data

2 series, 6 models

A series shares one design; the variants below differ by frame size and rating. This table is generated from the series definition — the variant list is never maintained by hand.

TF furnace transformer series

Oil-immersed furnace transformers with on-load tap changer, braced for repeated electrode short circuits.

3 variants
FrameRated powerkWRated voltageVVector groupInsulation classMasskg
TF-2500250010000Dd0F7800Details →
TF-8000800035000Dd0F19500Details →
TF-160001600035000Dd0H34000Details →

TR rectifier & isolation series

Dry cast-resin transformers for rectifier, isolation and traction duty, including 12- and 24-pulse arrangements.

3 variants
FrameRated powerkWRated voltageVVector groupInsulation classMasskg
TR-25025010000Dyn11F1150Details →
TR-1600160010000SpecialH4200Details →
TR-6300630035000SpecialH13500Details →
Downloads

Documentation for this family

PDFs supplement the pages above. Nothing here is required to establish whether a machine is a candidate.

  • CatalogueSpecial Transformers — Technical Catalogue
    PDF · 7.8 MB · Rev. 02 · updated 2025-12 · EN
    Download (mock)
  • Data sheetTF Furnace Transformer — Data Sheet
    PDF · 1.1 MB · Rev. 01 · updated 2025-12 · EN
    Download (mock)
  • QuestionnaireTechnical Questionnaire — Special Transformers
    PDF / online form · 0.3 MB · Rev. 01 · updated 2026-06 · EN
    Download (mock)
  • Data sheetTR Rectifier & Isolation — Data Sheet
    PDF · 1.0 MB · Rev. 02 · updated 2026-01 · EN
    Download (mock)
Related products

Ready to specify?

The enquiry form asks only the questions that apply to special transformers — including the hazardous-area section where it is relevant.