Zone 1 pump motor package, refinery expansion

Twenty-four flameproof motors for process pumps across a mixed IIB and IIC area classification.

Units
24
Rating range
15 – 132 kW
Gas groups
IIB and IIC
Delivery
16 weeks
The problem

The area classification drawing divided the unit between IIB and IIC areas, with two temperature classes. Earlier packages on the site had been delivered with a single specification, forcing re-certification of several positions after installation.

What was done

Each position was matched individually against the classification drawing before manufacture. Machines were nameplated with their position tag alongside the equipment marking, and the documentation pack was structured position by position rather than by order line.

Outcome

All twenty-four positions passed pre-commissioning audit on first inspection. The position-tagged documentation is now the client's standard requirement for subsequent packages.