Skip to content
ELECTROMASHElectrical machines since 1959
Water and Wastewater · 2026

Vertical pump motors, municipal abstraction plant

Six vertical motors with thrust bearings for deep-well abstraction, replacing failed units of mixed origin.

Units
6
Rating
75 kW each
Construction
IM V1 vertical
Spares lists
3 → 1
The problem

The station had six pumps from three suppliers with three different motor interfaces, and a history of thrust bearing failures traced to units originally specified for horizontal duty.

What was done

All six positions were standardised onto a single vertical series with correctly dimensioned thrust bearings, using adapter frames where the pump interfaces differed.

Outcome

Six positions now carry one spare-part list instead of three. No thrust bearing failure since commissioning.